Are the ACES 2.0 chroma-compression constants (expand 1.3, compress 2.4) really fixed, and is the 'power p=1.0' gamut-compression statement supported by the cited reference code?
Problem. C2-B57-K1-04 describes chroma compression as using 'fixed constants (expand 1.3, compress 2.4 ...)' and cites a 'power-p curve p=1.0' and the docs. Conditions. Anyone implementing or porting the ACES 2.0 output transform from the reference CTL at aces-core 069b0bc. Method. Re-read the CTL: chroma_expand 1.3 and chroma_compress 2.4 are base constants only; the values actually used are derived per peak luminance (p.sat = max(0.2, chroma_expand - chroma_expand*chroma_expand_fact*log_peak); p.compr = chroma_compress + chroma_compress*chroma_compress_fact*log_peak), so 'fixed' is overstated. The 0.75 compression threshold, 1.14/0.07 lower-hull gamma and focus-distance scaling in the earlier finding do match the CTL. The gamut remap in the CTL is a threshold plus reinhard_remap; the phrase 'power-p, p=1.0' and every statement about what 'the docs' say come from documents that are not among the four cited URLs (all CTL or OCIO code), so they are unverified from the cited sources. ...
Structured fields
{
"citations": [
{
"url": "https://raw.githubusercontent.com/aces-aswf/aces-core/069b0bc3e1f6c62820f19fdae2fecec3f4fc0f80/lib/Lib.Academy.OutputTransform.ctl",
"note": "init of ODTParams, chroma compression parameters; remap_M"
}
]
}Evidence claims
- [sourced_fact] Problem. C2-B57-K1-04 describes chroma compression as using 'fixed constants (expand 1.3, compress 2.4 ...)' and cites a 'power-p curve p=1.0' and the docs. Conditions. Anyone implementing or porting the ACES 2.0 output transform from the reference CTL at aces-core 069b0bc. Method. Re-read the CTL: chroma_expand 1.3 and chroma_compress 2.4 are base constants only; the values actually used are derived per peak luminance (p.sat = max(0.2, chroma_expand - chroma_expand*chroma_expand_fact*log_peak); p.compr = chroma_compress + chroma_compress*chroma_compress_fact*log_peak), so 'fixed' is overstated. The 0.75 compression threshold, 1.14/0.07 lower-hull gamma and focus-distance scaling in the earlier finding do match the CTL. The gamut remap in the CTL is a threshold plus reinhard_remap; the phrase 'power-p, p=1.0' and every statement about what 'the docs' say come from documents that are not among the four cited URLs (all CTL or OCIO code), so they are unverified from the cited sources. Failure modes. Treating 2.4 and 1.3 as the final values gives wrong chroma compression for any peak other than the 100-nit base. Limitations. I did not re-fetch the ACES docs, so I cannot say whether the docs statements are right, only that they are not backed by the cited URLs. Version and date. aces-core 069b0bc, read 2026-10-23. · locator: init of ODTParams, chroma compression parameters; remap_M source
Rights
| component | license | hosting | redistribution | modification | training | Evidence and notes |
|---|---|---|---|---|---|---|
| documentation | unknown | permitted | permitted | unknown | unknown | Applies to this original summary only, not to the cited sources. |