What do the safety bulletins say about overhead power lines, lighting rigged on aerial lifts, 480 V systems and PPE for lighting tasks, and where do they disagree?
Partially verified: the curator re-read S19; S15, S16, S17, S18 were not re-read by the curator and rest on the producer's pinned reading. Bulletin #22 (2017) allows lighting, camera and diffusion rigged onto boom-lift guardrails only within manufacturer limits with extra training (otherwise not at all), prohibits lifts over energised high-voltage lines, and says rigged lifts should not be operated over low-voltage lines (600 V or less). Clearance tables are in an Addendum A that #22 names as '#22 Addendum A' while the web URL labels it 23a (naming inconsistency kept).
Partially verified: the curator re-read S19; S15, S16, S17, S18 were not re-read by the curator and rest on the producer's pinned reading.
Bulletin #22 (2017) allows lighting, camera and diffusion rigged onto boom-lift guardrails only within manufacturer limits with extra training (otherwise not at all), prohibits lifts over energised high-voltage lines, and says rigged lifts should not be operated over low-voltage lines (600 V or less). Clearance tables are in an Addendum A that #22 names as '#22 Addendum A' while the web URL labels it 23a (naming inconsistency kept).
Curator qualifications: Partially verified: the curator re-read S19; S15, S16, S17, S18 were not re-read by the curator and rest on the producer's pinned reading. Curator GET 2026-10-23 of the sources not re-read (mechanical source evidence, not semantic verification): S15: HTTP 200, bytes equal to the producer pin; S16: HTTP 200, bytes equal to the producer pin; S17: HTTP 200, bytes equal to the producer pin; S18: HTTP 200, bytes equal to the producer pin. Documents read 2026-10-22; no legal conclusions; guidance only. Addendum A table text not in the fetched HTML (item-level gap); Addenda C (480 V) and D (PPE) from producer reading.
Limitations: Documents read 2026-10-22; no legal conclusions; guidance only.
Evidence status: statements located in the cited sources by a correlated desk review (Claude); not executed; not independently reviewed.
Structured fields
{
"citations": [
{
"url": "https://www.csatf.org/wp-content/uploads/2018/05/23ELECTRICAL.pdf",
"note": "Bulletin #22 Platforms (Revised September 5, 2017) Power Lines; Rigging and Cribbing for Aerial Boom Lifts Only"
},
{
"url": "https://www.csatf.org/23a_safety_bltn_power_line_distance_requirements/",
"note": "Bulletin #22 Platforms (Revised September 5, 2017) Power Lines; Rigging and Cribbing for Aerial Boom Lifts Only"
},
{
"url": "https://www.csatf.org/23c_safety_bltn_480_volt_systems/",
"note": "Bulletin #22 Platforms (Revised September 5, 2017) Power Lines; Rigging and Cribbing for Aerial Boom Lifts Only"
},
{
"url": "https://www.csatf.org/23d_safety_bltn_tasks_ppe/",
"note": "Bulletin #22 Platforms (Revised September 5, 2017) Power Lines; Rigging and Cribbing for Aerial Boom Lifts Only"
},
{
"url": "https://www.csatf.org/wp-content/uploads/2018/05/22PLATFORMS.pdf",
"note": "Bulletin #22 Platforms (Revised September 5, 2017) Power Lines; Rigging and Cribbing for Aerial Boom Lifts Only"
}
]
}Evidence claims
- [sourced_fact] Bulletin #22 (2017) allows lighting, camera and diffusion rigged onto boom-lift guardrails only within manufacturer limits with extra training (otherwise not at all), prohibits lifts over energised high-voltage lines, and says rigged lifts should not be operated over low-voltage lines (600 V or less). Clearance tables are in an Addendum A that #22 names as '#22 Addendum A' while the web URL labels it 23a (naming inconsistency kept). · locator: Bulletin #22 Platforms (Revised September 5, 2017) Power Lines; Rigging and Cribbing for Aerial Boom Lifts Only source
Rights
| component | license | hosting | redistribution | modification | training | Evidence and notes |
|---|---|---|---|---|---|---|
| documentation | unknown | permitted | permitted | unknown | unknown | Applies to this original summary only, not to the cited sources. |
Linked records
- cites → https://www.csatf.org/23a_safety_bltn_power_line_distance_requirements
- cites → https://www.csatf.org/23c_safety_bltn_480_volt_systems
- cites → https://www.csatf.org/23d_safety_bltn_tasks_ppe
- cites → https://www.csatf.org/wp-content/uploads/2018/05/22PLATFORMS.pdf
- cites → https://www.csatf.org/wp-content/uploads/2018/05/23ELECTRICAL.pdf