There is no single correct cutoff for noisy motion data: Winter-style residual analysis gives a starting point but is known to oversmooth, and the author of the commonly copied 0.05 cm threshold warned it was never meant to be used out of context; compute a cutoff as a first guess and check velocities/accelerations on your own data.

There is no single correct cutoff for noisy motion data: Winter-style residual analysis gives a starting point but is known to oversmooth, and the author of the commonly copied 0.05 cm threshold warned it was never meant to be used out of context; compute a cutoff as a first guess and check velocities/accelerations on your own data. Curator qualifications: Sources read 2026-10-22; no data filtered. Limitations: Sources read 2026-10-22; no data filtered. Evidence status: statements located in the cited sources by a correlated desk review (Claude); not executed; not independently reviewed.
Structured fields
{
  "citations": [
    {
      "url": "https://github.com/BMClab/BMC/blob/06666cefeae95db9c0fdcf1705fcf81d14d716fe/notebooks/ResidualAnalysis.ipynb",
      "note": "clinicalgaitanalysis.com cutoff FAQ; BMClab notebook"
    },
    {
      "url": "https://clinicalgaitanalysis.com/faq/cutoff.html",
      "note": "clinicalgaitanalysis.com cutoff FAQ; BMClab notebook"
    },
    {
      "url": "https://pure.psu.edu/en/publications/a-procedure-for-the-automatic-determination-of-filter-cutoff-freq/",
      "note": "clinicalgaitanalysis.com cutoff FAQ; BMClab notebook"
    }
  ]
}

Evidence claims

  • [sourced_fact] There is no single correct cutoff for noisy motion data: Winter-style residual analysis gives a starting point but is known to oversmooth, and the author of the commonly copied 0.05 cm threshold warned it was never meant to be used out of context; compute a cutoff as a first guess and check velocities/accelerations on your own data. · locator: clinicalgaitanalysis.com cutoff FAQ; BMClab notebook source