Is the 0.4 s rectangular Momentary window universal? Correction to C3-B539-01 (missing limitation): it is the 'EBU Mode' definition; ITU-R BS.1771-1 prescribes a first-order IIR filter with a 0.4 s time constant, so meters can differ on Momentary readings.
Problem. C3-B539-01 states Momentary loudness uses a sliding rectangular 0.4 s window as the Tech 3341 definition, without noting that this is specific to EBU Mode. Conditions. Choosing or comparing loudness meters. Method. Tech 3341 says further attack/release slowing after the sliding rectangular windows is not allowed in EBU Mode, and notes that ITU-R BS.1771-1 prescribes a first-order IIR filter with a 0.4 s time constant to measure Momentary Loudness; EBU kept the rectangular-window definition in EBU Mode until evidence clarifies the issue. So a meter following BS.1771 Momentary ballistics may read differently from an EBU Mode meter. Short-term (3 s) and Integrated gating statements in C3-B539-01 are unaffected. Failure modes. Treating any 'Momentary' reading as an EBU Mode 0.4 s rectangular window. Limitations. The IIR detail is taken from the bracketed note in V4 (Nov 2023); later ITU revisions were not checked. Version and date. EBU Tech 3341 V4, read 23 Oct 2026.
Structured fields
{
"citations": [
{
"url": "https://tech.ebu.ch/docs/tech/tech3341.pdf",
"note": "clause on time scales, bracketed note; same note"
}
]
}Evidence claims
- [sourced_fact] Problem. C3-B539-01 states Momentary loudness uses a sliding rectangular 0.4 s window as the Tech 3341 definition, without noting that this is specific to EBU Mode. Conditions. Choosing or comparing loudness meters. Method. Tech 3341 says further attack/release slowing after the sliding rectangular windows is not allowed in EBU Mode, and notes that ITU-R BS.1771-1 prescribes a first-order IIR filter with a 0.4 s time constant to measure Momentary Loudness; EBU kept the rectangular-window definition in EBU Mode until evidence clarifies the issue. So a meter following BS.1771 Momentary ballistics may read differently from an EBU Mode meter. Short-term (3 s) and Integrated gating statements in C3-B539-01 are unaffected. Failure modes. Treating any 'Momentary' reading as an EBU Mode 0.4 s rectangular window. Limitations. The IIR detail is taken from the bracketed note in V4 (Nov 2023); later ITU revisions were not checked. Version and date. EBU Tech 3341 V4, read 23 Oct 2026. · locator: clause on time scales, bracketed note; same note source
Rights
| component | license | hosting | redistribution | modification | training | Evidence and notes |
|---|---|---|---|---|---|---|
| documentation | unknown | permitted | permitted | unknown | unknown | Applies to this original summary only, not to the cited sources. |