Vendor manuals expose 75% vs 100% as a setting that must match the bar signal being fed (Tektronix WFM5200 and 1740A, Blackmagic SmartScope): the vectorscope graticule targets are drawn for one or the other. ITU-R BT.2111-3 (HDR bars) tabulates the codes: 100% bars use 940/64 and 75% bars use 721/64 at 10-bit (2884 at 12-bit), with a 40% grey, -2%/+2%/+4% black (PLUGE-like) steps and an explicit note that the pattern is not for black level setting. No SDR bar standard (e.g. SMPTE RP 219, ITU-R BT.801) was fetched, so the SDR 75% code values here are the worker's arithmetic from BT.709 s3.4.

Vendor manuals expose 75% vs 100% as a setting that must match the bar signal being fed (Tektronix WFM5200 and 1740A, Blackmagic SmartScope): the vectorscope graticule targets are drawn for one or the other. ITU-R BT.2111-3 (HDR bars) tabulates the codes: 100% bars use 940/64 and 75% bars use 721/64 at 10-bit (2884 at 12-bit), with a 40% grey, -2%/+2%/+4% black (PLUGE-like) steps and an explicit note that the pattern is not for black level setting. No SDR bar standard (e.g. SMPTE RP 219, ITU-R BT.801) was fetched, so the SDR 75% code values here are the worker's arithmetic from BT.709 s3.4. Curator qualifications: Excerpted evidence located (one unexcerpted row); 75%/100% bars and code values. Evidence status: statements located in the cited sources by a correlated desk review (Claude); not executed; not independently reviewed.
Structured fields
{
  "citations": [
    {
      "url": "https://download.tek.com/manual/WFM5200-waveform-monitor-user.pdf",
      "note": "candidate evidence excerpts"
    },
    {
      "url": "https://download.tek.com/manual/070847006_0.pdf",
      "note": "candidate evidence excerpts"
    },
    {
      "url": "https://documents.blackmagicdesign.com/UserManuals/SmartViewSmartScopeManual.pdf",
      "note": "candidate evidence excerpts"
    },
    {
      "url": "https://www.itu.int/dms_pubrec/itu-r/rec/bt/R-REC-BT.2111-3-202505-I!!PDF-E.pdf",
      "note": "candidate evidence excerpts"
    },
    {
      "url": "https://www.itu.int/dms_pubrec/itu-r/rec/bt/R-REC-BT.2100-3-202502-I!!PDF-E.pdf",
      "note": "candidate evidence excerpts"
    }
  ]
}

Evidence claims

  • [sourced_fact] Vendor manuals expose 75% vs 100% as a setting that must match the bar signal being fed (Tektronix WFM5200 and 1740A, Blackmagic SmartScope): the vectorscope graticule targets are drawn for one or the other. ITU-R BT.2111-3 (HDR bars) tabulates the codes: 100% bars use 940/64 and 75% bars use 721/64 at 10-bit (2884 at 12-bit), with a 40% grey, -2%/+2%/+4% black (PLUGE-like) steps and an explicit note that the pattern is not for black level setting. No SDR bar standard (e.g. SMPTE RP 219, ITU-R BT.801) was fetched, so the SDR 75% code values here are the worker's arithmetic from BT.709 s3.4. · locator: candidate evidence excerpts source