What do ITU-R BT.2408 and BT.2390 say about HDR-to-SDR down-mapping, do they cover dynamic metadata, and where is the BT.2390 EETF now?
BT.2408-8 section 5.2 says display-light down-mapping is usually preferred, that the monitoring down-mapper must match the one used to make the SDR transmission, and that a plain 0.5 linear scale does not preserve the look on a 100 cd/m2 display. Neither BT.2408-8 nor BT.2390-12 mentions dynamic metadata or trims (keyword counts of 0 for 'dynamic metadata' and '2094'); they are static, display-mapping guidance. The hermite-spline EETF that tools label 'BT.2390' appears in BT.2390 editions -5, -7 and -8 but in this extraction not in -9 to -12; BT.2408-8 Annex 5 carries it. This extends C2-B05-B-08 (BT.2100/2408/2446 reference-white and BT.2446 methods) without repeating it.
BT.2408-8 section 5.2 says display-light down-mapping is usually preferred, that the monitoring down-mapper must match the one used to make the SDR transmission, and that a plain 0.5 linear scale does not preserve the look on a 100 cd/m2 display. Neither BT.2408-8 nor BT.2390-12 mentions dynamic metadata or trims (keyword counts of 0 for 'dynamic metadata' and '2094'); they are static, display-mapping guidance. The hermite-spline EETF that tools label 'BT.2390' appears in BT.2390 editions -5, -7 and -8 but in this extraction not in -9 to -12; BT.2408-8 Annex 5 carries it. This extends C2-B05-B-08 (BT.2100/2408/2446 reference-white and BT.2446 methods) without repeating it.
Curator qualifications: Excerpted evidence located (one excerpt-less row); BT.2408-8 down-mapping guidance; no dynamic-metadata coverage stated.
Evidence status: statements located in the cited sources by a correlated desk review (Claude); not executed; not independently reviewed.
Structured fields
{
"citations": [
{
"url": "https://www.itu.int/dms_pub/itu-r/opb/rep/R-REP-BT.2408-8-2024-PDF-E.pdf",
"note": "candidate evidence excerpts"
},
{
"url": "https://www.itu.int/dms_pub/itu-r/opb/rep/R-REP-BT.2390-8-2020-PDF-E.pdf",
"note": "candidate evidence excerpts"
},
{
"url": "https://www.itu.int/dms_pub/itu-r/opb/rep/R-REP-BT.2390-12-2025-PDF-E.pdf",
"note": "candidate evidence excerpts"
},
{
"url": "https://github.com/haasn/libplacebo/tree/13d0b79827ea1671f991ca57700e5356af9731a5",
"note": "candidate evidence excerpts"
}
]
}Evidence claims
- [sourced_fact] BT.2408-8 section 5.2 says display-light down-mapping is usually preferred, that the monitoring down-mapper must match the one used to make the SDR transmission, and that a plain 0.5 linear scale does not preserve the look on a 100 cd/m2 display. Neither BT.2408-8 nor BT.2390-12 mentions dynamic metadata or trims (keyword counts of 0 for 'dynamic metadata' and '2094'); they are static, display-mapping guidance. The hermite-spline EETF that tools label 'BT.2390' appears in BT.2390 editions -5, -7 and -8 but in this extraction not in -9 to -12; BT.2408-8 Annex 5 carries it. This extends C2-B05-B-08 (BT.2100/2408/2446 reference-white and BT.2446 methods) without repeating it. · locator: candidate evidence excerpts source
Rights
| component | license | hosting | redistribution | modification | training | Evidence and notes |
|---|---|---|---|---|---|---|
| documentation | unknown | permitted | permitted | unknown | unknown | Applies to this original summary only, not to the cited sources. |
Linked records
- cites → https://github.com/haasn/libplacebo/tree/13d0b79827ea1671f991ca57700e5356af9731a5
- cites → https://www.itu.int/dms_pub/itu-r/opb/rep/R-REP-BT.2390-12-2025-PDF-E.pdf
- cites → https://www.itu.int/dms_pub/itu-r/opb/rep/R-REP-BT.2390-8-2020-PDF-E.pdf
- cites → https://www.itu.int/dms_pub/itu-r/opb/rep/R-REP-BT.2408-8-2024-PDF-E.pdf