What does the Hollywood Industry-Wide Labor-Management Safety Committee's portable-power bulletin say lighting crews must do on set, and how binding is it?
CSATF Bulletin #23 (2013, recommended guidelines, not law) says only authorised employees connect or operate distribution, rig de-energised and check for shorts before energising, connect grounds, neutrals then phases (reverse to disconnect), avoid tie-ins to energised premises power (qualified person required), never use alligator clips, and use GFCI protection for non-double-insulated tools on construction sites.
CSATF Bulletin #23 (2013, recommended guidelines, not law) says only authorised employees connect or operate distribution, rig de-energised and check for shorts before energising, connect grounds, neutrals then phases (reverse to disconnect), avoid tie-ins to energised premises power (qualified person required), never use alligator clips, and use GFCI protection for non-double-insulated tools on construction sites.
Curator qualifications: Documents read 2026-10-22; no legal conclusions; guidance only.
Limitations: Documents read 2026-10-22; no legal conclusions; guidance only.
Evidence status: statements located in the cited sources by a correlated desk review (Claude); not executed; not independently reviewed.
Structured fields
{
"citations": [
{
"url": "https://www.csatf.org/safety-bulletins/",
"note": "csatf.org Safety Bulletins index (live) introduction; Bulletin #23 Electrical (Revised August 20, 2013) pp.1-5, item 12"
},
{
"url": "https://www.csatf.org/wp-content/uploads/2018/05/23ELECTRICAL.pdf",
"note": "csatf.org Safety Bulletins index (live) introduction; Bulletin #23 Electrical (Revised August 20, 2013) pp.1-5, item 12"
},
{
"url": "https://www.csatf.org/wp-content/uploads/2018/05/GenCodeoSafePractices.pdf",
"note": "csatf.org Safety Bulletins index (live) introduction; Bulletin #23 Electrical (Revised August 20, 2013) pp.1-5, item 12"
}
]
}Evidence claims
- [sourced_fact] CSATF Bulletin #23 (2013, recommended guidelines, not law) says only authorised employees connect or operate distribution, rig de-energised and check for shorts before energising, connect grounds, neutrals then phases (reverse to disconnect), avoid tie-ins to energised premises power (qualified person required), never use alligator clips, and use GFCI protection for non-double-insulated tools on construction sites. · locator: csatf.org Safety Bulletins index (live) introduction; Bulletin #23 Electrical (Revised August 20, 2013) pp.1-5, item 12 source
Rights
| component | license | hosting | redistribution | modification | training | Evidence and notes |
|---|---|---|---|---|---|---|
| documentation | unknown | permitted | permitted | unknown | unknown | Applies to this original summary only, not to the cited sources. |