CSATF Bulletin #23 (2013, recommended guidelines, not law) says only authorised employees connect or operate distribution, rig de-energised and check for shorts before energising, connect grounds, neutrals then phases (reverse to disconnect), avoid tie-ins to energised premises power (qualified person required), never use alligator clips, and use GFCI protection for non-double-insulated tools on construction sites.

CSATF Bulletin #23 (2013, recommended guidelines, not law) says only authorised employees connect or operate distribution, rig de-energised and check for shorts before energising, connect grounds, neutrals then phases (reverse to disconnect), avoid tie-ins to energised premises power (qualified person required), never use alligator clips, and use GFCI protection for non-double-insulated tools on construction sites. Curator qualifications: Documents read 2026-10-22; no legal conclusions; guidance only. Limitations: Documents read 2026-10-22; no legal conclusions; guidance only. Evidence status: statements located in the cited sources by a correlated desk review (Claude); not executed; not independently reviewed.
Structured fields
{
  "citations": [
    {
      "url": "https://www.csatf.org/safety-bulletins/",
      "note": "csatf.org Safety Bulletins index (live) introduction; Bulletin #23 Electrical (Revised August 20, 2013) pp.1-5, item 12"
    },
    {
      "url": "https://www.csatf.org/wp-content/uploads/2018/05/23ELECTRICAL.pdf",
      "note": "csatf.org Safety Bulletins index (live) introduction; Bulletin #23 Electrical (Revised August 20, 2013) pp.1-5, item 12"
    },
    {
      "url": "https://www.csatf.org/wp-content/uploads/2018/05/GenCodeoSafePractices.pdf",
      "note": "csatf.org Safety Bulletins index (live) introduction; Bulletin #23 Electrical (Revised August 20, 2013) pp.1-5, item 12"
    }
  ]
}

Evidence claims

  • [sourced_fact] CSATF Bulletin #23 (2013, recommended guidelines, not law) says only authorised employees connect or operate distribution, rig de-energised and check for shorts before energising, connect grounds, neutrals then phases (reverse to disconnect), avoid tie-ins to energised premises power (qualified person required), never use alligator clips, and use GFCI protection for non-double-insulated tools on construction sites. · locator: csatf.org Safety Bulletins index (live) introduction; Bulletin #23 Electrical (Revised August 20, 2013) pp.1-5, item 12 source

Rights

componentlicensehostingredistributionmodificationtrainingEvidence and notes
documentationunknownpermittedpermittedunknownunknown

Applies to this original summary only, not to the cited sources.

Linked records

Machine-readable: JSON · Markdown · revisions · changes